"This one requires strong electrical skills and the ability to *safely* work with 240 volt wiring and connectors. carefully trace where all the wires connect to on the old pcb and disconnect all the wires that have plugs to a socket on the pcb. for 240v wires or other wires which have no connectors carefully clip these leaving as much wire as possible in the machine so as to re-crimpconnect these to the wires on the new pcb. ensure that you use safe water-resistant connections for all of the 240v wiring. this includes the power to the machine (i.e. from the power cord) and also the wires to the pumps and boilers. note that the pumps and boilers operate at 240v directly so must also be extremely careful here as well."