"Removed broken collar and fitted new one with short screwdriver. screws need to be very firmly in place otherwise the collar appears too big."
FILTER HOLDER COLLAR (Part the filter holder ESP8C/105 locks into)
Location Ref:
Exploded diagrams, Schematics and other documents
Installation
Trent
ACT
"Remove four philips head screws and separte collar from the machine. replace silicone steam ring if necessary. refit new collar ensuring screws are tightend firmly and evenly."
George
NSW
"4 screws - very easy!"
Liz
SA
"Undo 5 screws, clean area and replace with new ones."
Glen
VIC
"Undo mounting screws. remove old collar. fit new collar. refit mounting screws."
Deborah
QLD
"Very simple - only screwdriver required"
Geoff.
NSW
"1. remove water container and spill tray and lay machine on back. 2. remove 4 screws securing filter holder collar. 3. remove filter holder collar. 4. check new filter holder collar for raised casting protrusions. remove with file if necessary. 5. fit new filter holder collar with writing towards the front. 6. lubricate tabs of filter holder with vaseline. 7. stand machine upright and replace water container and spill tray. 8. fill with water and turn on. 9. without coffee in filter holder flush with water. 10. enjoy a coffee."
Warrren
VIC
"Unscrew and remove old collar replace with new"
Mel
QLD
"Unscrew 4 screws on filter holder collar and the one central screw holding in steam ring. refit new parts note as space between base collar is limited you need either a shortstubby or offset screwdriver. the benefit of doing this is also that it provides an opportunity to also clean a likely part-clogged primary filter that holds the steam ring in place."
Allan
NSW
"Undo 4 screws holding collar and remove. fit new collar and replace screws."