"Disconnect refrigerator from power. remove the unit re-connect all wiring to new unit re-install the unit back power up the refrigerator"
CONTROL BOARD/BOX ASSY.
Location Ref: 1
Exploded diagrams, Schematics and other documents
Installation
Trevor
NSW
"Turn off fridge and remove panel at back of freezer compartment. if core frozen, test thermostat switch with ohm meter - should be closed circuit. thaw out core with a hair dryer till all ice is gone. retest thermostat should be open circuit. thermostat ok. test defrost element for closed circuit - should have ohm meter reading not open circuit. replaced control board at bottom rear of fridge and had to reroute some cabling due to minor update to box."
Krishan
WA
"I had to call the professional"
Charles
WAIKANAE
"Fitting was a simple case of removing old unit - disconnect 3 multiplugs, reconnect to new unit and refit. only difference was that the new unit has three retaing screw holes to match two female screw holes."
Ian
VIC
"Very easy to fit. our fridge was not cooling in the upper part of the fridge but freezing the vege drawers. turns out this controller is a common failure."
Csaba
VIC
"If you can change a dvd drive on a computer... this is easier. three plug-in ports."
John
NORTH ISLAND
"See below as i have not received the part"
Chee
WA
"Unscrew previous component n replace"
Andrew
SA
"Very easy to replace yourself, is at the back down the bottom left side"
Steve
QLD
"Rear bottom of fridge next to compressor. original control box has extra plugs that werent needed so were cut off. the metal box had to be modified with pliers to allow cable entry. the rest just plugged in."