"Remove back cover of fridge unscrew support bracket remove damaged unit reverse order to install. other... ice maker did not start automatically.... removed ice maker plastic cover .. encouraged micro switch to operate .. all good now."
VALVE, WATER, TRIPLE
Location Ref: 1
Exploded diagrams, Schematics and other documents
Installation
Morris
VIC
"Turn off power, remove cover panel, unscrew valve unit, remove hoses and electrical connectors to solenoids, insert new valve and attach hoses solenoid connectors. test. replace back panel"
Derek
VIC
"If youre not mechanically minded take a photo before dismantling old valve so you can easily see how to reassemble the new valve"
Bill
SA
"Take a few photos of the assembly to remind you what it is supposed to look like when reassembled as there are 8 connections involved. by studying the replacement part you can clearly identify the number of pipe and electrical fittings. caution since you are removal electrical fittings turn off power to the fridge. note the pipes will leak water on removal so be prepared with a shallow tray or towel. prior to removing each connection from the old assembly i wrote down the connection (left right etc.) in marker pen on the connecting pipe or electrical connector. as you undo each connection you will appreciate that one or two pipes have less spare length to allow ready manipulation of the assembly so note these for doing up last when assembly the new part."